aMalcotransformers


Resin Casting Dry Type Power

Transformer

 

 

General :     

SC(B9),SC(B)10Resin casting dry type power transformer product by our company is a new generation of product in low loss and noise. Base on the FRVT processing technology imported from ABB-Micafil Co. in 90's, advanced technology of vacuum resin casting and L.V. foiled winding as well as the updated equipment such as GEORG cutting line, Stollberg winding machine and HUBR vacuum resin casting equipment all imported from Germany, and foiled winding machine imported from Italy, product performance is up to IEC726, GB6450, GB/T10228-1997 Standard.

The product owns its advantage such as low loss and noise, small size, less weight, moisture-proof, anti-dirty, crack-proof, withstanding impulse, flameproof, overload capability, smaller partial discharge (less than 10 PC).

It has reasonable structure and convenient operation& maintenance. When the BWK series temperature controlling system is provided for dry type transformer, it has more functions including alarming to faults and abnormal temperature, automatic tripping and automatic starting (stopping) fans to ensure its safe operation.

It is applicable to transmission and distribution system, hotel, restaurant, high building, commercial center, stadium, petrochemical factory, metro, station, airport, drilling form in the sea and so on, particular to the places of load center, or the places where require fireproofing specially.

SCB9 Transformer                                               SCB10 Transformer

 

Feature :

Adopting advanced technology and high quality raw material, with first class equipment and strict processing, SC-series resin casting dry type transformer owns the following advantages:

  1. Copper conductor is used both for H.V. &L.V. coils to strengthen the glass fiber. It is dried and cast by epoxy resin under the high vacuum. After curing, it is a firm cylinder, with high mechanical strength and withstanding short-circuit capability, smaller partial discharge, higher reliability as well as long service life.

  2. Flameproof, explosion resistant, no pollution to environment. Because the imported epoxy resin and glass fiber compound insulation materials are used and certain silicon powder is contained in the epoxy resin. Heat conduction co-efficient and flameproof ability is greatly improved in comparison with old type materials. There would be no toxin and harmful gas caused by resin under high temperature.

  3. The moist cannot be absorbed by coils. The core clamp is coated with the special anti-corrosive materials so it can do as usual under the severe conditions. It is unnecessary to get rid of moisture for interval operation.
      
  4. Good capabilities of withstanding short-circuit and lightning impulse.

  5. Good heating dissipation due to thin resin coated on the outside of coils. Normally, natural air cooling (AN) is taken. Fan cooling system could be provided with the transformer in any protection grade to improve short time overload ability and ensure the safe operation.

  6. Low loss and noise, energy saving, economical operation, free from maintenance.

  7. Small size, less weight, little occupied area, and few cost for installation. It is unnecessary to take consideration of drainage pool, fire proof and fire fighting facilities, as well as standby power source.

  8. Without any risk of fire disaster, explosion, it could also be installed separately around loading center, close to electric consuming place, so the wiring costs can be reduced and more costs can be saved.

Type designation :

Technical parameter :


Specification :
    Voltage class : 6 -35KV
    Capacity range : 30 - 10000KVA
    Voltage adjustment mode : No-load tap changer or on-load tap changer (fitted with vacuum or on-load tap changer )
    Tapping range : +/- 2x2.5%        +/- 4x2.5% (or others)
    Frequency : 50Hz or 60Hz
    Phase number : Three phase
    Vector group : Yyn0; Dyn11; Yd11 or others
    Short-circuit impedance : Standard impedance ( requirement by customer)
    Working condition  : relative humidity 100%, ambient temperature no more than 40 degrees centigrade   
    Max. temperature rise  : 100K
    Cooling mode : natural air cooling (AN) or  fan cooling (AF)
    Protection grade  : IP00; IP20(indoor ); IP23(outdoor)
    Insulation grade  : F grade
    Insulation level :
    10KV  Power frequency withstanding voltage 35KV, impulse withstanding voltage 75KV;
    20KV  Power frequency withstanding voltage 50KV, impulse withstanding voltage 125KV;
    35KV  Power frequency withstanding voltage 70KV, impulse withstanding voltage 170KV;

Technical parameter of 10kV product :

SC(B)9 Series

H-V: 10(10.5,11,6,6.3,6.6) +/- 2X2.5%kV
Vector group: Y,yn0  or  D,yn11

L-V: 0.4kV        Insulation level: LI75AC35/LI0AC3

Type

No-load loss

Load loss
(120
degrees centigrade)

Impedance

voltage

No-load current

Noise

Outline dimension (proper body)

W

W

%

%

dB(A)

L x W x H x track gauge

SC9-30/10

200

745

4

2.2

43

700x460x750x400

SC9-50/10

300

1050

4

2.0

43

945x750x950x550

SC9-80/10

380

1450

4

1.8

43

945x750x945x550

SC9-100/10

430

1660

4

1.8

44

945x750x965x550

SC9-125/10

520

1950

4

1.6

44

1040x860x1045x660

SC9-160/10

600

2250

4

1.4

44

1040x860x1085x660

SC9-200/10

700

2670

4

1.4

45

1040x860x1115x660

SC9-250/10

800

2800

4

1.4

45

1170x860x1120x660

SC9-315/10

940

3660

4

1.2

47

1240x760x1305x660

SCB9-400/10

960

4210

4

1.2

48

1320x760x1390x660

SCB9-500/10

1150

5150

4

1.2

48

1360x760x1455x660

SCB9-630/10

1320

6180

4

1.0

50

1460x760x1500x660

SCB9-630/10

1280

6300

6

1.0

50

1460x760x1480x660

SCB9-800/10

1500

7330

6

1.0

52

1520x920x1590x820

SCB9-1000/10

1760

8590

6

0.8

54

1600x920x1720x820

SCB9-1250/10

2060

10190

6

0.8

54

1660x920x1895x820

SCB9-1600/10

2400

12370

6

0.8

56

1800x920x1985x820

SCB9-2000/10

3200

15230

6

0.6

57

1800x920x2135x820

SCB9-2500/10

3800

18090

6

0.6

57

2070x1170x2180x1070

 

SC£¨B£©10 Series

H-V: 10(10.5,11,6,6.3,6.6) +/- 2X2.5%kV ¡¡
Vector group: Y,yn0 or D,yn11

L-V: 0.4kV     Insulation level: LI75AC35/LI0AC3

Type

No-load

loss

W

Load loss
(120
degrees centigrade)

W

Impedance

voltage

%

No-load

current

%

Noise

dB(A)

Outline dimension
  (proper body)

Lx W x H x track gauge

SC10-30/10

200

700

4

2.2

43

700x460x750x400

SC10-50/10

285

985

4

2.0

43

945x750x950x550

SC10-80/10

365

1375

4

1.8

43

945x750x945x550

SC10-100/10

405

1570

4

1.8

44

945x750x965x550

SC10-125/10

480

1830

4

1.6

44

1040x860x1045x660

SC10-160/10

560

2120

4

1.4

44

1040x860x1085x660

SC10-200/10

650

2520

4

1.4

45

1040x860x1115x660

SC10-250/10

760

2750

4

1.4

45

1170x860x1120x660

SC10-315/10

880

3455

4

1.2

47

1240x760x1305x660

SCB10-400/10

960

3985

4

1.2

48

1320x760x1390x660

SCB10-500/10

1150

4875

4

1.2

48

1360x760x1455x660

SCB10-630/10

1320

5870

4

1.0

50

1460x760x1500x660

SCB10-630/10

1280

5950

6

1.0

50

1460x760x1480x660

SCB10-800/10

1500

6950

6

1.0

52

1520x920x1590x820

SCB10-1000/10

1760

8120

6

0.8

54

1600x920x1720x820

SCB10-1250/10

2060

9685

6

0.8

54

1660x920x1895x820

SCB10-1600/10

2400

11720

6

0.7

55

1800x920x1985x820

SCB10-2000/10

3200

14430

6

0.5

55

1800x920x2135x820

SCB10-2500/10

3800

17060

6

0.5

56

2070x1170x2180x1070


Ordering Notes :

      1.Type
      2.Rated capacity
      3.Phase number, rated frequency
      4. Rated voltage(L.V. &H.V.)
      5.Vector group
      6.Short-circuit impedance
      7.Cooling mode
      8.Temperature controlling and indicating device ( with computer interface or not)
      9.Protection degrade and enclosure material ( its color)
      10.Service condition: elevation height, environmental temperature, etc
      11.Ordering quantity and delivery time
      12.Special requirement